Killtest 는 한번에 통과하지 못하면 전액 환불한다는 약속을 합니다. 만약에 우리시험문제E20-817 를 구매하고 처음으로 시험을 통과하지 못하면 PROMETRIC 나 VUE 시험 센터에서 도장을 찍은 성적표로 우리들의 E20-817 Symmetrix Business Continuity Expert Exam for Storage Admins 시험 문제를 구매했던 금액을 전액 환불해 줄 것입니다. 고객에게 아무런 손해를 보지 않도록 할 것입니다.
VUE/Prometric Code: E20-817
Exam: Symmetrix Business Continuity Expert Exam for Storage Admins
Q&A:173 Q&As
8. Your customer requests an immediate point-in-time copy of their production Oracle database but
cannot have the application brought down.
Which Enginuity feature allows the creation of restartable copies without quiescing the database?
A.Double Checksum
B.Enginuity Consistency Assist
C.Multi-Session Consistency
D.Symmetrix Differential Data Facility Answer: B
9. An application has a BC requirement of two independent full concurrent copies of production each night.
One copy is mounted up for backup and recovery (BURA); the other is mounted up on a target server for
data warehouse operations.
The current STD device configuration is a four-member mirrored meta. The current BCV device
configuration is a four-member unprotected meta. The Symmetrix has global hot sparing enabled.
Which local EMC replication product(s) will enable the same number of replications as well as an
additional SRDF device?
A.Symmetrix Optimizer
B.TimeFinder/Clone
C.TimeFinder/Snap
D.TimeFinder/SRDF
Answer: B
10. You are designing an SRDF service level plan for a customer. Their needs assessment shows the
following:
Performance: Remote replication with potential impact, depending on distance and network latency for
synchronous leg
Availability: Zero data exposure in the event of a source failure; no data loss on a single point of failure
Functionality: Continuous real-time mirroring on synchronous leg, Unlimited distances with no additional
host impact for asynchronous leg, and the ability to synchronize between two remote sites
Economics: Requires sufficient bandwidth to support peak workload requirements
Which SRDF mode of operation should be chosen?
A.SRDF/A
B.SRDF/DM
C.SRDF/S
D.SRDF/Star
Answer: D 11. A company migrates their Windows 2003 Exchange servers. After this has been completed the
systems administrator notes that performance has degraded on one of the Exchange servers. Analysis
indicated that the system is performing two reads or writes for transactions 15% of the time.
What is the probable cause?
A.Block size is too small.
B.Read cache is turned off.
C.Sectors are misaligned.
D.Stripe size is too small.
Answer: C
12. A company had their SRDF links go down while the R1BCV was in the process of synchronizing with
the STDR2. A few minutes later the TimeFinder Integration Module for Exchange found inconsistencies in
the information store of the local STDR1 device. The SRDF link comes back up.
What must the storage administrator do next?
A.Restore the STD from the STDR2.
B.Establish the R1BCV with the STDR2.
C.Keep the data from becoming unusable at the remote location.
D.Split the BRBCV from the STDR2.
Answer: A
E20-817 덤프다운로드바로가기: http://www.killtest.kr/EMCCertification/E20-817.asp